CP-134U/CP-134U-I
4-port RS-422/485 Universal PCI w/
2 KV Isolation Protection |
|
 |
Quickview |
 |
|
|
|
 |
 |
First 2 ports configurable for either RS-232 or RS-422/485 |
 |
Top Performance with 128-byte FIFO and On-chip H/W, S/W Flow Control |
 |
PComm Lite utility for easy management and software development |
|
 |
|
| |
 |
Introduction |
 |
|
| |
The CP-134U and CP-134U-I of Smart
Multiport Serial Boards is used by Industrial
Automation system integrators for designing long
distance, multi-point PC-based data acquisition applications.
On-chip Automatic Data Direction Control for Precision RS-485 Communication
RS-485 communication requires precise timing control to enable and disable the line driver. Powered by Moxa's Turbo Serial Engine™ chip that comes with on-chip ADDC™ (Automatic Data Direction Control), sending RS-485 packets over CP-134U is as easy as using RS-232.
RS-485 multidrop for up to 31 devices within 1.2 km
The CP-134U Universal PCI Multiport Serial Board has 4 RS-422/485 serial ports, each capable of data rates up to 921.6 Kbps. In RS-485 mode, the serial port can connect up to 31 daisychained RS-485 devices within a range of 1.2 km. For long distance RS-485 communication, optional 2 KV isolation protection is available (CP-134U-I) to prevent equipment damage.
More info >>
|
|
Back to Top |
 |
Features |
 |
|
|
 |
Over 700 Kbps data throughput, for top performance |
|
 |
4-port RS-422/485 interface with ADDC™ and up to 921.6 Kbps |
|
 |
2-wire/4-wire RS-485 communication up to 1.2 km |
|
 |
Built-in 15 KV ESD and optional 2 KV optical isolation protection |
|
 |
128-byte FIFO and on-chip H/W, S/W flow control |
|
 |
Universal PCI compatible with 3.3/5V PCI and PCI-X |
|
 |
Windows 2003/XP/2000/98/ME, Linux, Unix driver support |
|
|
| |
Back
to Top
|
 |
Specifications
|
 |
|
|
Hardware |
|
|
|
| MOXA UART MU860 (16C550C comaptible) |
|
|
|
|
|
|
|
| |
Interface |
|
|
|
|
|
|
| 4 (only one IRQ required) |
|
|
|
|
|
|
|
| TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
|
|
|
|
| TxD+(B), TxD-(A), RxD+(B), RxD-(A), RTS+(B),RTS-(A), CTS+(B), CTS-(A), GND |
|
|
|
|
| TxD+(B), TxD-(A), RxD+(B), RxD-(A),GND |
|
|
|
|
|
|
|
| |
Performance |
|
|
|
| |
Configuration |
|
|
|
|
|
|
|
|
|
|
|
|
| None, Even, Odd, Space, Mark |
|
|
|
|
|
|
|
| |
Operating Systems |
|
|
|
| Windows Vista (X86 & X64), Windows NT/2000/XP/2003, Windows 95/98/ME, Linux 2.4/2.6 (Redhat, SuSe), FreeBSD 4.x, Windows XP Embedded, DOS |
|
|
|
|
| |
Power and Environment |
|
|
|
|
|
|
|
|
|
| -20 to 85°C (-4 to 185°F) |
|
|
|
|
|
|
| Embedded 15KV ESD Protection |
|
|
|
|
CP-134U: 120 x 82.5 mm (4.72 x 3.24 in)
CP-134U-I: 120 x 115 mm (4.72 x 4.52 in) |
|
|
|
|
| EN55022 Class B, EN55024, EN6100-3-2, EN61000-3-3, FCC Part 15 Class B |
|
|
|
|
|
|
| |
Power Consumption |
|
|
|
| |
|
 |
Ordering
Information
|
 |
|
| |
CP-134U |
|
| 4-port RS-422/485 Board (DB9 or DB25 cable included) |
|
CP-134U-I |
|
| 4-port RS-422/485 Board with
2 KV Isolation Protection (DB9 or DB25 cable included) |
|
|
|
| Software and Documentation CD-ROM |
|
|
|
| |
Optional Connectors (choose one per board) |
|
|
|
| 4-port male DB9 connection cable |
|
|
|
| 4-port male DB25 connection cable |
|
|
|
| |
|
|
|